Choose your MIDI Input and Output ports and channels here — Output should be connected to the Midi2CV's MIDI IN port, and Input to its MIDI OUT port. The Input is needed to receive the device's replies: firmware version and settings (Query device) and tune data (Receive from device). Port and channel choices are remembered by the browser.
Channel messages (notes, CCs, pitch bend, aftertouch, program change) received on the Input channel are passed through to the Output, re-channeled to the Output channel — so a MIDI keyboard on the Input can play the Midi2CV while this page is open. Set the Input channel to Any to accept every channel. SysEx is always processed regardless of the channel setting. Other system messages, such as MIDI clock, are not passed through. Pass-through is paused while a firmware update is being sent.
The Output channel is also the channel the LFO and EG tabs send their CCs on, so it should match the device's own MIDI channel (see the Device tab).
A second, optional Input port (Input2) with its own channel filter is available for setups that need two independent MIDI sources feeding in at once — for example, the Midi2CV's MIDI OUT on Input and a MIDI controller keyboard on Input2. Set a port to None to disable it.
The green LED at the end of each port row lights up on MIDI activity: on an Input, for SysEx and for channel messages that pass its channel filter; on the Output, for every message sent.
The Learned MIDI CC list below the ports shows every MIDI CC binding created via MIDI Learn: turn on the MIDI Learn checkbox next to the tabs (learnable LFO and EG fields get a blue border), click an LFO or EG field to focus it, then move a control on your MIDI controller. From then on that CC drives the field just as if you had edited it, sending the corresponding CC to the device; a bound CC is not passed through to the Output itself. Turn MIDI Learn back off once you're done — existing bindings keep working.
Each entry shows the CC number, the field it drives, its own activity LED, and a × button to forget that one binding (or use Clear to forget all of them at once). A binding to a field with only a few values (CV routing, waveshape, segment curve, loop mode) also gets Absolute / Step buttons: Absolute maps the CC's own 0-127 value onto the field's range, while Step advances the field by one value each time the bound button is pressed, wrapping back around after the last one — useful for controllers that only ever send a fixed 0/127 pair rather than sweeping a range.
Query device asks the Midi2CV for its firmware version and current settings, filling in every field on the Device, LFO and EG tabs from the reply, then also fetches its tune data (see the Tune Data tab). The firmware version is shown below the firmware update buttons. Requires a MIDI Input connected to the device's MIDI OUT.
Reset device restores all device settings to their factory defaults. Use Query device afterwards to refresh the fields on this page.
Updating the firmware is a two-step process: first click Request firmware update and confirm that the device LEDs blink alternately — the device is now waiting for new firmware — then click Update firmware and wait for the transmission to complete. Progress is shown below the buttons, along with a Cancel button. When more than one firmware version is available, pick the one to send from the drop-down next to the buttons; otherwise the only available version is shown there instead. Download saves the selected firmware release (a .zip file) to disk, for updating the device with another SysEx tool.
Below the buttons are the device settings and options, starting with the device's own MIDI channel (which the MIDI tab's Output channel should match). A change to any of them is sent to the device right away. Defaults resets all of them to their default values and sends those to the device. For what each setting and option does, see the Midi2CV Mk2 MIDI Control Reference.
These fields control the Midi2CV's LFO. Each change is sent to the device right away as a MIDI CC on the MIDI tab's Output channel, and the text next to each field shows what its current value means (routing, waveshape, rate in Hz — or as a note length when synced to MIDI clock — and so on). Type a value, use the field's up/down arrows, or click a field and drag up or down to sweep through its range. Defaults resets every LFO field to its default value and sends those to the device.
Every LFO field can also be bound to a CC on your MIDI controller with MIDI Learn (see the MIDI section above). For what each parameter does and its CC number, see Midi2CV Mk2 LFO MIDI CC Numbers.
These fields control the Midi2CV's envelope generator. Each change is sent to the device right away as a MIDI CC on the MIDI tab's Output channel, and the text next to each field shows what its current value means (routing, segment times in ms or seconds, sustain and amplitude levels in percent, segment curve, loop mode, sync note length, and so on). As on the LFO tab, type a value, use the field's up/down arrows, or click a field and drag up or down to sweep through its range. Defaults resets every EG field to its default value and sends those to the device.
Every EG field can also be bound to a CC on your MIDI controller with MIDI Learn (see the MIDI section above). For what each parameter does and its CC number, see Midi2CV Mk2 Envelope (EG) MIDI CC Numbers.
Tune data is the Midi2CV's per-note tuning table: one correction value for each of the 128 MIDI notes, added to that note's pitch CV. All zeros gives the standard 1V/Oct scale; other tables can trim individual notes to match a particular oscillator, or reshape the whole scale (e.g. 1.2V/Oct or Hz/V). The device stores its table and applies it to every note it plays; individual notes can also be tuned by ear via MIDI CCs, see the Midi2CV Mk2 MIDI Control Reference.
Receive from device reads the device's current table (it's also fetched automatically by Query device on the Device tab). Load from file opens a .tunedata file from disk. Once a table is loaded either way, its values and description are shown below the buttons, and Send to device writes it to the Midi2CV, replacing its current table, while Save to file saves it to a .tunedata file — e.g. to back up a table you tuned by ear before experimenting with another one.
The drop-down list offers ready-made tables: pick one and click Load (choosing an entry also loads it), then Send to device. Available tables are 1V/Oct (the standard scale, all zeros), 1.2V/Oct (Buchla) and Hz/V (the linear scale used by vintage Korg and Yamaha synthesizers, which requires the 0-10V output range: Note CV jumper at the left position).
A .tunedata file is plain text: optional leading # comment lines describing
the table (shown below the buttons and kept when saving), followed by 128
comma-separated values, one per MIDI note from 0 to 127.